    What are boiler fault codes?

    Boiler fault codes are alphanumeric or numeric indicators generated by a boiler’s control system to communicate specific issues or malfunctions within the heating system. These codes help both homeowners and service professionals identify and diagnose problems quickly, allowing for efficient troubleshooting and repair.

    Ferroli Boiler Error codes

    Ferroli boilers are known for their excellent design which is aesthetically pleasing. However, boilers of top quality do something tend to have certain issues. On this page you will find the error codes or faults of Ferroli boilers and what they indicate, in addition to possible ways to fix these issues.

    Dante Ferroli first established the company in 1955. The original head office is situated in San Bonifacio, close to the Italian city of Verona. Ferroli has a network of branches which operates in over 14 countries across Asia and Europe. That is why they are a well-known manufacturer in the heating industry.

    Their main aim, for over 60, has been to lead an innovative approach in the heating industry and to manufacture appliances which are highly efficient, well-built and suitable to a wide range of specifications.

    Ferroli takes great pride in their ability to provide fantastic service to its customers. In 2017, the Ferroli BlueHelix Tech 25C was voted to be the best boiler and as well as the Best Purchase in the Italian magazine of AltroConsumo.

    Read more: The Best Brands of System Boilers & Pricing

    Ferroli Boiler Error Codes
    Ferroli Boiler Error Codes / Fault Codes List 4

    What are Ferroli iBoiler Error Codes?

    Ferroli Bluehelix Tech Error Codes

    Fault CodeThe ProblemPossible cause
    A01No burner ignitionNo gas or ignition – issue with detection electrode, faulty gas valve or insufficient gas supply pressure
    A02Flame signal present with burner offElectrode error or PCB error
    A05Fan errorNo 230V power supply or tachometric signal interrupted fan damaged or out of balance
    A06No flame after the ignition phaseIonisation electrode fault – flame unstable or air/flue ducts obstructed or condensate trap or pipes blocked
    F07 – F14 – A07High flue gas temperatureThe flue gas probe detects excessive temperature
    F08 – A08Overtemperature protection interventionHeating sensor damaged – no water circulation in the system or air in the system
    F09 – A09Overtemperature protection interventionReturn sensor damaged – no water circulation in the system or air in the system
    F10 – A10Flow sensor errorSensor damaged – wiring shorted or wiring disconnected
    F11 – A11Return sensor faultSensor damaged – wiring shorted or wiring disconnected
    F12DHW sensor errorSensor damaged – wiring shorted or wiring disconnected
    F13 – A13Flue probe faultProbe damaged – wiring shorted or wiring disconnected
    A14Flue extraction duct safety device intervention
     
    Fault F07 generated 3 times in the last 24 hours
    F34Supply voltage under 170VElectric mains trouble
    F37Incorrect system water pressurePressure too low – water pressure switch either damaged, blocked or not connected
    F39Optional external probe errorProbe damaged or wiring shorted – probe disconnected after activating the outside temperature mode
    F41Activation of maximum ELTA T protectionHeating sensor damaged, return sensor damaged, no water circulation as air in the system
    F42 – A42Sensor control protection activationHeating sensor damaged, return sensor damaged or disconnected
    F43Exchanger protection interventionNo system water circulation – air in system
    A23 – A24 – A26 – F15 – F21 – F40 – F47 – F50 – F51 – F53Printed circuit board (PCB) parameter faultWrong PCB parameter setting
    F56 – A56Calibration error/calibration procedure not completedIncorrect parameters electrode damaged or not correctly positioned
    F61 – A61Printed circuit board (PCB) AGC01 errorPCB AGC01 internal error
    A54 – A55 – A63Printed circuit board (PCB) AGC01 faultPCB AGC01 fault
    F67Boiler chip card (BCC) service key connected
    F68 – A68Boiler chip card (BCC) service key faultError loading BCC service key file
    A62No communication between PCB and gas valvePCB not connected – valve damaged, replace the valve
    A64Maximum number of consecutive resets exceededMaximum number of consecutive resets exceeded
    F66Firmware not loaded successfully

    Ferroli iBoiler Error Codes

    Fault CodeThe Problem
    A01Ignition error – possible electrode fault or power too low, no gas or excessive condensate level
    A02Electrode or card error
    A03Heating sensor damaged, no water circulation or air in the system
    F04Wrong card parameter setting
    F05Air pressure switch contact error – wrong flue baffle obstructed or not correctly sized
    A06No flame after the ignition phase – low pressure in gas system burner minimum pressure setting
    F07Air pressure switch error – contacts closed on activation of fan
    A09Gas valve error – wiring could be disconnected or error with gas valve
    F10Delivery sensor error, sensor damaged wiring shorted or disconnected
    F11Domestic hot water (DHW) sensor error – sensor damaged, wiring shorted or disconnected
    A15Fault F05 generated 5 times within the last 24 hours – possible error with the air pressure switch
    A16Gas valve error – wiring disconnected or faulty gas valve
    A23Card parameter error – possibly wrong card parameter setting
    A24Card parameter error – possibly wrong card parameter setting
    F34Supply voltage under 170V – electric mains error
    F35Faulty mains frequency – electric mains error
    F37Error with system water pressure, possible pressure too low or water pressure switch is damaged
    F43Exchanger protection intervention – could be because no system water circulation or there’s air in the system
    F50Controller DBM23B error – controller could have an internal error
    F51Controller DBM23B error – controller could have an internal error

    Read more: Combi boilers common faults  

    Ferroli Modena HE Combi Error Codes

    Fault CodeThe Problem
    A01No burner ignition – possibly no gas, detection or ignition electrode fault, defective gas valve, incorrect inlet gas pressure
    A02Flame detected with the burner off – possibly caused by ionisation, defective electrode or mainboard defective. Check the printed circuit board (PCB) or ionizing electrode wiring
    A03High limit protection – flow temperature sensor not active, incorrectly located or no system circulation. Check the position of the flow sensor or check pump and radiator valves
    A04Flue gas fault – could be because F07 happened 3 times in the last 24 hours – check the flue
    A05Fan problem – tachometer signal interrupted for 1 hour or longer – check the wiring and the fan
    A06No flame after ignition phase – possible causes: detection electrode fault, flame unstable, incorrect valve gas offset, flue gas circuit
    A41Flow sensor disconnected – check the correct positioning and operation of the flow sensors
    A42Flow sensor fault – sensor needs changing
    F07High fume temperature – the exchanger probe detects an excessive temperature for over 2 minutes – check the exchanger.
    F10Flow sensor fault – possible causes: sensor damaged, short-circuited or wiring broken check the wiring
    F11Return sensor fault – sensor wiring shorted or broken – check the wiring
    F12Domestic hot water (DHW) sensor fault – sensor damaged, wiring shorted or wiring disconnected – check the wiring
    F13Exchange probe fault – wiring shorted or wiring broken – check wiring
    F14Fan problem – tachometer signal interrupted fan connection. Fan damaged or debris in fan – check the wiring, the fan and clean debris
    F15Supply voltage under 170v – electric supply problem – the electrical system needs checking
    F34Irregular mains frequency – possible electric supply problem – the electrical system needs checking
    F35Incorrect system water pressure – the possible cause is pressure too low or sensor damaged – the system may need filling or check the sensor
    F37External probe fault sensor damaged or short-circuited – check the wiring
    F39Exchanger protection activation – possibly caused by no system circulation, the air in the system or sensor damaged
    F43Flow sensor fault – sensor damaged – sensor needs changing
    F52Controller 041049G0 fault – controller internal error
    A61No communication between controller and gas valve controller – could not be connected or valve damaged
    A62Controller 041049G – internal error
    A63 – A64 – F66 Controller DBM12 fault

    Read about: Intergas Boiler Error Codes / Fault

    Ferroli Modena HE System Error Codes

    Fault CodeThe Problem
    A01No burner ignition – possible electrode error, defective gas valve or incorrect inlet gas pressure
    A02Flame detected with the burner off – electrode defective main board defective
    A03High limit protection – possible flow temperature sensor not active or incorrectly located, no system circulation
    A04Flue gas fault – fault F07 happened 3 times in the last 24 hours
    A05Fan error – tachometer signal interrupted for 1 hour or longer
    A06No flame after the ignition phase – electrode error, flame unstable, incorrect valve gas offset or flue gas circuit obstructed
    A41Flow sensor error – sensor disconnected
    A42Flow sensor error – sensor damaged
    F07High fume temperature – the exchanger probe detects an excessive temperature
    F10Flow sensor error – sensor damaged, short-circuited, sensor damaged or wiring broken
    F11Return sensor error – t-sensor damaged, short-circuited, sensor damaged or wiring broken
    F13Exchanger probe error – t-sensor damaged, short-circuited, sensor damaged or wiring broke
    F14Flow sensor error – t-sensor damaged, short-circuited, sensor damaged or wiring broken
    F15Fan problem – tachometer signal interrupted fan connection or damaged debris in fan. You need to check and clean fan debris
    F34Supply voltage under 170v – electric supply error
    F35Irregular mains frequency – electric supply problem
    F37Incorrect system water pressure error – possible sensor damaged or pressure too low
    F43Exchanger protection activation – no system circulation air in the system
    F52Flow sensor – fault sensor damaged
    A61Controller ABM03B error – controller has an internal error
    A62No communication between controller and gas valve – controller not connected or valve damaged
    A63 – A64 – F66Controller ABM03B error – controller internal error

    Read about: Ravenheat Boilers Error Codes / Fault Codes List

    Ferroli Discontinued Boiler Error Codes of:

    • DOMIcondens HE 26 C
    • OPTIMAX HE PLUS 31C boiler
    • OPTIMAX HE PLUS 38C boiler.
    BoilersFault CodeThe Problem
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31CA01No burner ignition
    OPTIMAX HE PLUS 38CA01The burner fails to light
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA02Flame present signal with burner off, possible electrical fault
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA03Over-temperature protection activation
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31CA04Fume thermostat fault
    OPTIMAX HE PLUS 38CA04Fume extraction duct safety device activation
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31CA05Fan fault or fume pressure switch fault
    OPTIMAX HE PLUS 38CA05Fan protection activated
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA06No flame after the ignition phase
    OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF07High fume temperature
    DOMIcondens HE 26 CF07Card parameter
    DOMIcondens HE 26 CA09Gas value fault
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF10Delivery sensor 1 fault
    DOMIcondens HE 26 CF11DHW sensor fault
    OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF11Return sensor fault
    OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF13Fume sensor fault
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF14Delivery sensor 2 fault
    OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF15Fan fault
    DOMIcondens HE 26 CA16Gas valve fault
    DOMIcondens HE 26 CF20Combustion control fault
    DOMIcondens HE 26 CA21Poor combustion fail
    DOMIcondens HE 26 CA23Set nominal system water pressure not reached within 4 minutes
    DOMIcondens HE 26 CA244 fillings within 24 hours
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA34Supply voltage under 170V / 180V
    DOMIcondens HE 26 CA35Faulty mains frequency
    OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA35Mains frequency anomaly
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA37Incorrect system water pressure
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA39External probe fault
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA41Sensor positioning
    DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF42Heating sensor fault
    DOMIcondens HE 26 CA43Exchange protection activation
    DOMIcondens HE 26 CA50Gas valve fault
    DOMIcondens HE 26 CA51Poor combustion fault
    OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA62No communication between electronic controller and gas valve  

    However, in some cases, getting a new boiler might be more cost-effective than getting your old boiler fixed. Some issues might be costly to fix. What is more, a new boiler will probably be more efficient and can help you save both money and energy. That is why getting a new boiler is a good investment in the long run.

    Read about: Common Sime Boiler Error Codes

    Best combi boilers & boiler brands

    How to reset a Ferroli Boiler?

    Resetting a Ferroli boiler is a common procedure to address certain issues or errors. Here are general steps to reset a Ferroli boiler:

    1. Locate the Reset Button:
      • Find the reset button on your Ferroli boiler. This button is often on the control panel or near the display.
    2. Turn Off the Boiler:
      • Switch off the boiler using the main power switch or by turning off the electricity supply to the unit.
    3. Wait for a Few Seconds:
      • Allow the boiler to remain off for about 10-15 seconds. This brief pause helps reset the internal electronics.
    4. Press and Hold the Reset Button:
      • Press and hold the reset button. While holding it down, turn the boiler back on.
    5. Continue Holding Until Reset:
      • Keep the reset button pressed until you see a change in the display or until the boiler goes through its reset sequence. This may take a few seconds.
    6. Release the Reset Button:
      • Once the reset process is complete, release the reset button.
    7. Monitor the Boiler:
      • Observe the boiler’s operation to see if the issue has been resolved. Check for any error codes or fault indicators.

    Read more: Main Boiler Error Codes / Fault Codes

    Navien Boiler Error Codes / Fault Codes

    Ferroli Boiler Error Codes
    Ferroli Boiler Error Codes / Fault Codes List 5

    Get a quote from smartadapt. We have a large range of products and our staff of Gas Safe engineers provides an excellent service that is both professional and reliable. In addition, we can help you get the boiler that best fits your house and heat requirements.

    Read about: Ariston Boiler Error and Fault Codes

    Biasi Boiler Error Codes / Fault Codes 

    Keston Boiler Error Codes / fault codes

    FAQs

    Do Ferroli still make boilers?

    Italian boiler manufacturer Ferroli has been at the leading edge of heating appliance design and development for more than half a century and now operates in over 100 countries worldwide.

    Why won’t my Ferroli boiler fire up?

    If your boiler is failing to fire up and just going into lock-out, it can be a problem with the PCB (printed circuit board), but you can check this by testing with a vault meter to see if electricity is reaching the PCB whilst still remaining unresponsive.

    What pressure should my Ferroli boiler be?

    Your boiler gauge should show that the boiler pressure is between 1.0 and 2.0. If the pressure drops below 1.0, then you’ll need to repressurise it.